Optimum Tech Services
Optimum Tech Services
Visakhapatnam, Andhra Pradesh
GST No. 37ECPPK2017E1ZO
TrustSEAL Verified
Call 07942955969 78% Response Rate
SEND EMAIL

CBRN GAS FILTERS

Offering you a complete choice of products which include cbrn gas mask filter nbc-77 sof 40mm thread - 20 year shelf life.

CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life

CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life
  • CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life
  • CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life
  • CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life
Get Best Quote
Approx. Price: Rs 7,999 / PieceGet Latest Price
Product Brochure

Product Details:

Minimum Order Quantity100 Piece
StyleEN 14387+A1
BrandMIRASAFETY
TypeA2B2E2K2HgSXP3DRREACTOR
ColorBlack
SizeSTANAG 4155 (EN 148- 1)- Rd 40x1/7
Weight335 g +-5%
Is It With FilterWith Filter
Cover AreaUnmatched 20 year shelf life for cost-saving, long term storage
Model Name/NumberNBC-77 SOF 40mm Thread
Usage/ApplicationTYPE AND CLASS PARTICLE FILTER EFFICIENCY @ FLOW RATE 95L/M
Diameter110 mm
Height85 mm
Storage time20 years (factory sealed)
BREATHING RESISTANCE IN PA@ flow rate 30l/min. EN 1) NBC-77 SOF 260 <140
BREATHING RESISTANCE IN PA@ flow rate 95l/min. EN 1) NBC-77 SOF 980 <600

NBC-77 SOF GAS MASK FILTER KEY FEATURES:
  • Compatible with standard 40mm NATO threaded respirators, which are widely available.
  • 20-year shelf life - save money long-term by not having to replace your filters every 5 years
  • Used by military personnel, CBRN specialists, and special operations forces all over the world
  • Filter all known CBRN agents, including radioactive iodine, rated for A2B2E2K2HgSXP3 D R.
  • Certified by European agencies and has the “CE” symbol. Compliant under EN 14387:2004 + A1:2008

Note:
1) Standard EN 14387+A1
2) The filter was tested on dolomite dust clogging
3) Radioactive iodine and its organic compound - methyliodide¹³¹ acc. to standard DIN 58621

NBC-77 SOF GAS MASK FILTER APPLICATION:

The filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic - diphenyldichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.

GAS MASK FILTER LIFETIME:

Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

GAS MASK FILTER STORAGE AND MAINTENANCE:

Each NBC-77 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.


GAS MASK FILTER DISPOSAL:

After use, gas mask filters are considered special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.

 

Request
Callback


Additional Information:

  • Item Code: 8421
  • Production Capacity: 500
Yes! I am Interested
X

Product Videos

Explore More Products

View All Products
Tell Us What Are You Looking For ?




Reach Us
Komarthi Satya (CEO)
Optimum Tech Services
58-2-28/1, Syam Nagar Raminaidu Colony, Marripalem
Visakhapatnam - 530008, Andhra Pradesh, India
Get Directions

Call Us


Send E-mail